Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract Processes of magma generation and transportation in global mid‐ocean ridges are key to understanding lithospheric architecture at divergent plate boundaries. These magma dynamics are dependent on spreading rate and melt flux, where the SW Indian Ridge represents an end‐member. The vertical extent of ridge magmatic systems and the depth of axial magma chambers (AMCs) are greatly debated, in particular at ultraslow‐spreading ridges. Here we present detailed mineralogical studies of high‐Mg and low‐Mg basalts from a single dredge on Southwest Indian Ridge (SWIR) at 45°E. High‐Mg basalts (MgO = ∼7.1 wt.%) contain high Mg# olivine (Ol, Fo = 85–89) and high‐An plagioclase (Pl, An = 66–83) as phenocrysts, whereas low‐Mg basalts contain low‐Mg# Ol and low‐An Pl (Fo = 75–78, An = 50–62) as phenocrysts or glomerocrysts. One low‐Mg basalt also contains normally zoned Ol and Pl, the core and rim of which are compositionally similar to those in high‐Mg and low‐Mg basalts, respectively. Mineral barometers and MELTS simulation indicate that the high‐Mg melts started to crystallize at ∼32 ± 7.8 km, close to the base of the lithosphere. The low‐Mg melts may have evolved from the high‐Mg melts in an AMC at a depth of ∼13 ± 7.8 km. Such great depths of magma crystallization and the AMC are likely the result of enhanced conductive cooling at ultraslow‐spreading ridges. Combined with diffusion chronometers, the basaltic melts could have ascended from the AMC to seafloor within 2 weeks to 3 months at average rates of ∼0.002–0.01 m/s, which are the slowest reported to date among global ridge systems and may characterize mantle melt transport at the slow end of the ridge spreading spectrum.more » « less
-
Dudley, Edward G. (Ed.)ABSTRACT Effective disinfection technology to combat severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can help reduce viral transmission during the ongoing COVID-19 global pandemic and in the future. UV devices emitting UVC irradiation (200 to 280 nm) have proven to be effective for virus disinfection, but limited information is available for SARS-CoV-2 due to the safety requirements of testing, which is limited to biosafety level 3 (BSL3) laboratories. In this study, inactivation of SARS-CoV-2 in thin-film buffered aqueous solution (pH 7.4) was determined across UVC irradiation wavelengths of 222 to 282 nm from krypton chloride (KrCl*) excimers, a low-pressure mercury-vapor lamp, and two UVC light-emitting diodes. Our results show that all tested UVC devices can effectively inactivate SARS-CoV-2, among which the KrCl* excimer had the best disinfection performance (i.e., highest inactivation rate). The inactivation rate constants of SARS-CoV-2 across wavelengths are similar to those for murine hepatitis virus (MHV) from our previous investigation, suggesting that MHV can serve as a reliable surrogate of SARS-CoV-2 with a lower BSL requirement (BSL2) during UV disinfection tests. This study provides fundamental information on UVC’s action on SARS-CoV-2 and guidance for achieving reliable disinfection performance with UVC devices. IMPORTANCE UV light is an effective tool to help stem the spread of respiratory viruses and protect public health in commercial, public, transportation, and health care settings. For effective use of UV, there is a need to determine the efficiency of different UV wavelengths in killing pathogens, specifically SARS-CoV-2, to support efforts to control the ongoing COVID-19 global pandemic and future coronavirus-caused respiratory virus pandemics. We found that SARS-CoV-2 can be inactivated effectively using a broad range of UVC wavelengths, and 222 nm provided the best disinfection performance. Interestingly, 222-nm irradiation has been found to be safe for human exposure up to thresholds that are beyond those effective for inactivating viruses. Therefore, applying UV light from KrCl* excimers in public spaces can effectively help reduce viral aerosol or surface-based transmissions.more » « less
-
null (Ed.)Ultraviolet (UV) devices emitting UVC irradiation (200− 280 nm) have proven to be effective for virus disinfection, especially on surfaces and in air, due to their rapid effectiveness and limited to no material corrosion. Numerous studies of UV-induced inactivation focused on nonenveloped viruses. Little is known about UVC action on enveloped viruses across UVC wavelengths. In this study, we determined inactivation efficiencies of two coronaviruses (ssRNA) and an enveloped dsRNA bacteriophage surrogate in buffered aqueous solution (pH 7.4) using five commonly available UVC devices that uniquely emit light at different wavelengths spanning 222 nm emitting krypton chloride (KrCl*) excimers to 282 nm emitting UVC LEDs. Our results show that enveloped viruses can be effectively inactivated using UVC devices, among which the KrCl* excimer had the best disinfection performance (i.e., highest inactivation rate) for all three enveloped viruses. The coronaviruses exhibited similar sensitivities to UV irradiation across the UVC range, whereas the bacteriophage surrogate was much more resistant and exhibited significantly higher sensitivity to the Far UVC (<230 nm) irradiation. This study provides necessary information and guidance for using UVC devices for enveloped virus disinfection, which may help control virus transmission in public spaces during the ongoing COVID-19 pandemic and beyond.more » « less
An official website of the United States government

Full Text Available